What a D and C tray is designed to support
A D and C tray is a gynecology instrument set prepared for dilation and curettage, a procedure in which the cervix is dilated and tissue is removed or sampled from the uterine lining with a curette or suction method. The exact D and C tray instruments vary by facility policy, physician preference, patient factors, and whether the case is diagnostic, therapeutic, or suction-assisted. Most trays, however, follow the same basic workflow: visualization, cervical stabilization, uterine assessment, dilation, tissue removal, specimen handling, and post-procedure accounting.
For sterile processing, purchasing, nursing education, and procedure-room planning, a D and C tray should not be treated as a fixed universal kit. It is a controlled set that needs to match the intended procedure, manufacturer instructions for use, institutional count policy, and recognized infection prevention guidance.

This article is an informational instrument guide for healthcare content readers and should not be used as a clinical procedure manual. For related device education, see the site’s Instruments section.
Core instruments commonly found in a D and C tray
Authoritative patient and clinical education sources, including ACOG and major academic medical centers, describe dilation and curettage as involving cervical access and tissue removal with a curette or suction device. Commercial and humanitarian gynecology set lists also show recurring instrument categories. Names, sizes, and quantities differ, but the functional groups are generally consistent.
| Instrument category | Common examples | Primary role in the tray | Key planning note |
|---|---|---|---|
| Vaginal speculum or retractor | Graves speculum, Sims speculum, Auvard weighted speculum | Provides visualization and access to the cervix | Selection depends on exposure needs, patient anatomy, and provider preference |
| Cervical holding instrument | Tenaculum, Pozzi forceps, Schroeder tenaculum | Stabilizes the cervix during assessment and dilation | Tips must be inspected for alignment, damage, and secure closure |
| Uterine measuring instrument | Sims uterine sound or graduated uterine sound | Assesses uterine depth and direction when used by the clinician | Graduation marks should be visible and not obscured by wear |
| Cervical dilators | Hegar dilators, Pratt dilators, tapered dilators | Gradually dilate the cervical canal | Trays should include the size range required by the procedure plan |
| Curettes | Sharp uterine curettes, blunt curettes, Sims curettes, Recamier curettes | Remove or sample uterine tissue | Loops and edges require careful inspection for burrs, bending, or corrosion |
| Forceps and clamps | Sponge forceps, tissue forceps, ring forceps | Assist with preparation, handling gauze, or managing materials on the sterile field | Hinges and ratchets should open, close, and lock smoothly |
| Suction-related items | Suction cannula, tubing, collection system components | Used when the case is suction-assisted rather than only sharp curettage | Single-use and reusable components must never be confused |
| Basic accessory items | Instrument tray, basin, specimen container support items, gauze as supplied by policy | Support setup, tissue handling, and field organization | Items included in the count must match the facility count sheet |
The tray should be reviewed as a working system, not as a loose list of tools. A complete curette set is of limited value if the dilator range is incomplete. A well-matched dilator set does not compensate for a damaged tenaculum. The practical value of the tray comes from having the right instruments, in functional condition, arranged according to policy, and verified before use.
How diagnostic, therapeutic, and suction-assisted trays differ
The phrase D and C tray can refer to several related but not identical setups. A diagnostic D and C is often associated with tissue sampling for abnormal uterine bleeding or evaluation of endometrial tissue. A therapeutic D and C may be used to remove retained tissue in selected clinical circumstances. Some cases use sharp curettage, while others involve suction-assisted evacuation with a cannula and suction source.
In a sharp curettage setup, curette selection is especially important. Facilities may stock multiple loop sizes so the clinician can match the instrument to the anatomy and purpose of sampling. Sharp curettes require close inspection because the working edge is central to their function and can also present a safety risk if damaged or handled improperly.
In a suction-assisted setup, the tray may include or be paired with suction cannulas, suction tubing, collection containers, adapters, and a suction source. These items are often managed differently from reusable stainless-steel instruments. Many suction cannulas and tubing components are single-use devices. Other parts may be reusable only when the labeling and facility policy permit reprocessing. The FDA’s reprocessing guidance emphasizes device-specific instructions rather than generic cleaning assumptions.
Some facilities separate items into a base D and C tray and preference-card add-ons. For example, specula, dilators, curettes, and tenacula may be standard, while suction components, specialty retractors, local anesthetic supplies, or ultrasound-related accessories may be added according to the planned case. This approach can reduce unnecessary instruments in the set, but only if the preference card is maintained and reviewed when clinical practice changes.
Instrument condition checks that matter before use
A D and C tray contains narrow, pointed, hinged, and sometimes sharp instruments. Inspection is therefore more than a cosmetic step. The tray must support safe function, accurate counting, and reliable reprocessing.
- Specula and retractors: Check for smooth surfaces, stable screws or locking mechanisms, and absence of cracks, corrosion, or bent blades.
- Tenacula and forceps: Confirm that tips align, jaws meet as intended, ratchets hold securely, and box locks are free of soil or stiffness.
- Uterine sounds: Verify that the instrument is not unintentionally bent and that depth markings remain legible.
- Dilators: Confirm the sequence is complete, sizes are identifiable, and tips are smooth without burrs or deformation.
- Curettes: Inspect loops for sharpness where appropriate, structural integrity, corrosion, and secure attachment to the handle.
- Suction components: Check package integrity for sterile single-use items and verify compatibility among cannula, tubing, and collection components.
Inspection should also include tray layout. Heavy instruments should not crush delicate items. Pointed instruments should be protected in a way that does not interfere with sterilization or leave residue. Hinged instruments should be positioned according to sterile processing policy and manufacturer instructions. If a facility uses a count sheet, every reusable item should be identifiable by name, size, and quantity.
Reprocessing and sterility considerations for reusable instruments
D and C tray instruments that enter sterile tissue or contact mucous membranes require careful infection prevention controls. CDC guidance classifies surgical instruments that contact sterile tissue as critical items requiring sterilization, and it identifies steam sterilization as the preferred method for many heat- and moisture-tolerant critical instruments. This does not mean every item in a D and C-related setup follows the same process. The correct method depends on device design, material, labeling, and validated instructions for use.
Reusable stainless-steel instruments usually move through point-of-use handling, transport, decontamination, cleaning, inspection, assembly, packaging, sterilization, storage, and distribution. Cleaning is separate from sterilization; retained blood, tissue, or debris can interfere with later processing. Hinges, serrations, lumens, joints, and textured handles need particular attention because soil can remain in small spaces.
AAMI ST79 is widely referenced in the United States for steam sterilization and sterility assurance practices in healthcare facilities. FDA guidance for reusable medical devices also stresses validated, device-specific reprocessing instructions. In practical tray management, teams should avoid undocumented shortcuts such as mixing single-use suction items with reusable instruments, substituting packaging without approval, or processing an instrument when the facility lacks clear instructions.
Documentation is part of safety. Load records, sterilization indicators, maintenance logs, count sheets, and tray assembly records create traceability when a question arises. If an instrument is found damaged, missing, wet, contaminated, or improperly packaged, the tray should be managed under facility policy rather than informally completed in the procedure room.
Counting, traceability, and retained item prevention
Although many D and C procedures are shorter than major open operations, instrument accountability still matters. WHO surgical safety materials include confirmation of instrument, sponge, and needle counts when applicable, and AORN guidance addresses standardized procedures to prevent unintentionally retained surgical items. Facility policy determines which items are counted, when counts occur, and how discrepancies are reconciled. See also: Implants.
For a D and C tray, count accuracy depends on a realistic tray list. If a set includes multiple small dilators or curettes that look similar, the count sheet should identify them clearly. If a provider preference card adds instruments outside the standard tray, those items should be incorporated into the count process rather than treated as informal extras. If a component breaks, the fragments must be accounted for according to policy.
Traceability also supports quality improvement. Repeated missing dilators may indicate a storage or assembly problem. Recurrent corrosion on curettes may suggest an issue with cleaning chemistry, water quality, or drying. Frequent preference-card changes may show that the base tray no longer reflects actual practice. Reviewing these patterns turns tray management from simple restocking into risk reduction.
Practical specification points for purchasing or tray standardization
When comparing D and C tray instruments, procurement teams should avoid judging sets only by item count. A larger set is not automatically more useful, and a smaller set is not automatically more efficient. The better question is whether the tray supports the procedures actually performed at the facility.
- Clinical fit: Confirm whether the tray is intended for diagnostic curettage, therapeutic curettage, suction-assisted procedures, or a mix of cases.
- Size range: Review dilator and curette sizes, not just the presence of those categories.
- Material and finish: Stainless-steel quality, corrosion resistance, surface finish, and clear markings affect durability and inspection.
- Reprocessing compatibility: Every reusable item should have accessible instructions for cleaning, inspection, packaging, and sterilization.
- Replacement planning: High-wear items such as curettes, tenacula, and hinged forceps need a replacement pathway.
- Tray weight and layout: Overloaded trays can complicate handling, drying, and storage.
- Standard naming: Consistent instrument names reduce confusion among sterile processing, nursing, and purchasing teams.
Standardization can reduce variation, but it should not erase legitimate clinical differences. A hospital, ambulatory surgery center, and office-based procedure room may all use D and C-related instruments, yet their tray configuration, sterilization workflow, and emergency backup needs may differ. The safest standard is specific enough to be inspected and counted, while still flexible enough to match approved procedure types.
Common mistakes when describing a D and C tray
One common mistake is using D and C tray as if it always means the same instrument list. In reality, published set lists and supplier catalogs differ. Some emphasize sharp curettes and dilators; others include suction-related accessories; some place specula or weighted retractors in a separate wrapped set.
A second mistake is confusing instrument identification with clinical instruction. Knowing that a uterine sound measures depth or that a tenaculum stabilizes the cervix does not define when or how it should be used. Those decisions belong to qualified clinicians following applicable standards of care.
A third mistake is overlooking reprocessing details. A tray may look complete but still be unsuitable if an instrument is damaged, labeling is missing, a sterile barrier is compromised, or single-use components are mixed into a reusable workflow. For content, training, and purchasing purposes, the instrument list should always be paired with condition, sterility, and traceability considerations.
Frequently asked questions
What instruments are usually in a D and C tray?
A typical D and C tray may include a vaginal speculum or retractor, tenaculum, uterine sound, cervical dilators, uterine curettes, sponge forceps, tissue forceps, and supporting tray accessories. Suction cannulas and tubing may be included or supplied separately for suction-assisted cases.
Are all D and C trays the same?
No. Tray contents vary by facility policy, procedure type, clinician preference, and whether the setup is for diagnostic curettage, therapeutic curettage, or suction-assisted evacuation. The tray should match the approved preference card and the device instructions for use.
What is the difference between a curette and a suction cannula?
A curette is an instrument used to scrape or sample tissue. A suction cannula is connected to suction equipment to remove tissue or fluid through aspiration. Some procedures may involve suction, curettage, or both, depending on the clinical plan.
Why are dilator sizes important in a D and C instrument set?
Dilators are used to open the cervical canal gradually. A missing or poorly marked size can interrupt workflow and create confusion. Facilities should verify that the dilator range in the tray matches the intended procedures and that all markings remain legible.
Can reusable D and C instruments be sterilized like other surgical instruments?
Many reusable stainless-steel gynecology instruments can be steam sterilized when their labeling permits it, but the correct process must follow the manufacturer’s instructions and facility policy. Cleaning, inspection, packaging, sterilization, storage, and documentation all matter for safe reuse.